The PT2X is powered internally with two AA batteries or with an auxiliary power supply for data intensive applications. Envco offers alkaline, rechargeable, and other auxiliary power systems. At the rate of four measurements per hour, the unit will run for a year on its internal AA batteries.
FEATURES
• RS485/RS232 interface
• Small diameter
• Pressure, temperature & time
• 130,000+ records / non-volatile
• 316 stainless steel, Viton and Teflon construction
• MODBUS protocol for RTU & PLC applications
• Easy export to spreadsheets and databases
The PT2X comes with powerful, easy-to-use, Windows based Aqua4Plus software, affording the user extensive control, including real time monitoring, flexible programming, easy field calibration, and a delayed start feature. Aqua4Palm is available for Palm based handhelds, allowing the user to create test sessions, examine data, and monitor real time readings with the convenience and portability of a PDA.
APPLICATIONS
Due to its rugged construction, proven reliability, and datalogging capability, the AquiStar PT2X can be used to replace analog sensors with separate dataloggers. Units can be used to monitor groundwater, well, tank and tidal levels, as well as for pump testing and flow monitoring.
The transmitter's end cone is interchangeable with a 1/4" NPT inlet which allows for increased application use and easy hookup.The modular designed AquiStar PT2X can be factory serviced and repaired saving on future upgrade and repair costs.
MECHANICAL
TRANSMITTER
Body Material 316 stainless steel
Wire Seal Materials Viton and Teflon
Desiccant High- and standard- capacity packs
Terminating Connector Available
Weight .8lbs.
ELECTRICAL
Pressure
Static Accuracy +/-0.1% FSO (maximum) (B.F.S.L. 25C)* +/-0.06% FSO (typical) 0.06% available on request.
Temperature Error +/-0.5% FSO (maximum) (reference 25C) +/-0.25% FSO (typical) Maximum +/-0.25% FSO Zero Offset at 25C
Resolution 16 bit
Over Range Protection 2x (except300 PSIA)
Temperature Accuracy
+/-0.75C (maximum)
Resolution 0.1C
Time
Accuracy +/-4 min/yr (maximum) +/-2 min/yr (typical)
Recommended Operating Temperature Range 0C to 40C
Ordering Information
Titanium PT2X Water Level Logger
Twist Open 0.75” diam. 0.1% FSO 1 MB Memory
3C385TTi 20 PSIA
3C371TTi 30 PSIA
316 Stainless Steel PT2X Water Level Logger
0.1% FSO Twist Open 0.75” diam. 1 MB Memory
3C370T 20 PSIA
3C371T 30 PSIA
3C372T 50 PSIA
3C373T 100 PSIA
3C374T 300 PSIA
0.1% FSO Set Screw 0.84” diam. 1 MB Memory
3C370 20 PSIA
3C371 30 PSIA
3C372 50 PSIA
3C373 100 PSIA
3C374 300 PSIA
Economy 316 Stainless Steel PT2X Water Level Logger
0.25% FSO Twist Open 0.75” diam. 512 KB Memory
3C377T 20 PSIA
3C378T 30 PSIA
3C379T 50 PSIA
3C380T 100 PSIA
3C381T 300 PSIA
0.25% FSO Set Screw 0.84” diam. 512 KB Memory
3C377 20 PSIA
3C378 30 PSIA
3C379 50 PSIA
3C380 100 PSIA
3C381 300 PSIA
PSIA = Absolute pressure is zero referenced against a perfect vacuum, so it is equal to gauge pressure plus atmospheric pressure
PSIG = Gauge pressure is zero referenced against ambient air pressure, so it is equal to absolute pressure minus atmospheric pressure. Negative signs are usually omitted. A gauged sensor must have a vented cable.
Use the request button on product pages to build a quote request list.