Applications:
• Borehole and pipeline monitoring
• Effluent monitoring
• River and stream measurements
Specification Model ORP100
Range +/- 500mV
Temperature Range 0-40C
Accuracy +/- 10mV (or +/- 0.2mA)
Supply Voltage 8-15VDC Reverse polarity protected-Surge protected to 2kV
Quiescent Current 12 mA
Warm up time to stable reading 2 Seconds
Output 4-20mA
Wetted Materials 316 Stainless steel, Delrin
Dimensions length 206 mm,
S/S body 31.8 mm OD
Delrin body 38 mm OD
Output Load (min-max) 0-500 ohms at 14V
0-400 ohms at 12V
Storage Temperature - 20 to +60C
Ordering Information
ORP Range Please specify Range: +/- 500mV, +/- 1,000mV or 0 - 1000mV
700-0912 ORP100 Output 4-20mA, Bare Wire Connection as Standard
Specify Cable Length
Ancillary Equipment
SDI-100 SDI-12 Converter Box - provides SDI-12 output from 4 - 20mA sensor
Options for ORP Sensors
FOR ALL ORP SENSORS Optional WP7 Connector (Note a Detachable WP7 Cable will be required as well)
Use the request button on product pages to build a quote request list.
| 0 Items | $0.00 |